Electric Fireplace Installation: A Planning Guide by Type

Dimplex Ignite XL 50-inch built-in linear electric fireplace

Short answer: how an electric fireplace is installed depends on which of three types you buy. A wall-mounted unit hangs on a bracket and usually plugs into an outlet, so a handy homeowner can often do it. A recessed or built-in linear unit needs a framed opening, finishing work and, in most cases, hardwiring by a licensed electrician. A firebox for an existing masonry fireplace slides into the old opening once you have power there and the chimney is sealed off. Pick the type first, because it decides who you hire, what you buy and the order of the work.

This guide walks through each type using the installation manuals for the fireplaces Lumiflares carries. It is a planning overview. The manual that ships with your fireplace, your local code and your installer have the final word.

The three ways to install an electric fireplace

Wall-mounted Recessed or built-in Into an existing fireplace
Wall opening needed? No Yes: a framed opening in a stud wall or a framed chase No new opening; uses the old firebox
Electrician? Not for a plug-in unit near an outlet that can carry the load. Yes to hardwire, add an outlet or run a new circuit Usually. Many built-ins are designed to be hardwired, and some can only be hardwired Yes if an outlet is needed inside or beside the firebox, or for 240V
Other trades None for most jobs Carpenter or builder for framing; drywall, tile or stone installer for finishing Chimney professional to clean, inspect and seal the flue
Typical tools and skills Stud finder, level, drill, anchors suited to the wall; two people to lift Framing, cutting a header if you open an existing wall, drywall or tile finishing Careful measuring, shims, trim fitting
Models we carry TriVista Pictura 60, Astound FlexMount 50, Allusion Slim Ignite XL, Evolve and Ultra; Astound Built-In; Allusion Slim, Platinum and Edge; Scion; Triton; Revillusion 30 to 42; Ignite Aspire; Inception 36 Revillusion 24, Element 42

Not sure whether your wall can take a recessed unit? Our guide to wall-mounted vs recessed electric fireplaces compares wall depths with each model's framing depth.

Type 1: Wall-mounted installation

This is the quickest route to a fire on the wall. The unit hangs on a metal bracket that is screwed to the wall, and the main planning job is power.

What the manuals say

  • Napoleon TriVista Pictura 60: hangs on the included bracket. Napoleon's manual says to screw the bracket into studs where possible, with the hooks up and level, and to use the supplied plastic anchors only where studs aren't available. It plugs into a 120V outlet and Napoleon calls for a dedicated 15-amp grounded circuit with no extension cord. The manual also includes 120V hardwiring instructions if you want the cord hidden.
  • Napoleon Astound FlexMount 50: can be wall-mounted now, or partly or fully recessed later. Napoleon's manual says to use screws into studs where present, otherwise anchors and drywall screws, and recommends checking with a local builder because wall materials vary. Napoleon lists it as plug-in at 120V or hardwired at 120V or 240V. The unit alone weighs 74.5 lb, so plan on two people.
  • SimpliFire Allusion Slim: ships with a wall-mount bracket as well as recess brackets. The manual requires at least six screws or toggle anchors for the 40, 50 and 60-inch sizes (eight for the 72), with at least two landing on framing. Toggle bolts need at least 1/2-inch drywall. The supplied masonry anchors are for solid brick or concrete only, not hollow block.

Steps and who does them

  1. Choose the spot (you): check the 36-inch clearance to furniture and curtains in front, and what will go above. If a TV is planned, see sizing an electric fireplace under a TV.
  2. Plan the outlet (you, or an electrician): a plug-in unit needs a grounded outlet the cord can reach directly. To hide the cord, an electrician can place an outlet behind the unit or hardwire it.
  3. Mount the bracket (you or a handyman): find studs, level the bracket, fasten per the manual.
  4. Hang and secure the unit (two people): hook it on and fit any locking screws the manual calls for.
  5. Add media and glass where the model ships them separately, then test.

Type 2: Recessed or built-in installation

Recessed linear fireplaces give the cleanest look and suit media walls, but they turn the job into a small construction project. The deciding number is framing depth:

Model Framing depth (manufacturer) What that means
Allusion Slim Recesses into 2x4 framing with at least 1/2-in. sheathing Goes into a standard interior wall
Ignite XL and Ignite Evolve 5-1/2 in. for flush; 3-1/2 in. partly recessed with optional trim Flush in a 2x6 wall; stands slightly proud in a 2x4 wall
Allusion Platinum and Allusion Edge 5-1/2 in. minimum (2x6) 2x6 wall or a build-out
Scion 7-5/8 in. rough opening depth Framed chase or bump-out
Triton 12-15/16 in. Framed chase; 1, 2 or 3-sided
Astound Built-In 13-3/8 in. minimum Framed chase

Traditional-style fireboxes, including the Revillusion 30 to 42, the Ignite Aspire and the SimpliFire Inception 36, also install in a framed opening. The Aspire 42, for example, calls for an opening 42-3/4 in. wide, 47 in. high and 18 in. deep. The Inception can alternatively sit on a finished wall inside SimpliFire's optional Wescott mantel kit.

The order of work differs by model

This is the detail most often missed. Some fireplaces go in before the wall is finished, and some only after it is painted. Get it wrong and you are cutting finished drywall or tile.

Model Sequence in the manual Finishing note
Dimplex Ignite XL Frame, route the supply wire with at least 18 in. of slack, set and level the unit, screw it to the studs, complete wiring, then fit glass and media Decorative material such as brick can overhang the face by no more than 1/2 in.
Napoleon Astound Built-In Frame, attach brackets and set the unit, hardwire, finish the wall, then media, glass and trim. Napoleon says each step must be completed before the next Finishing must not overhang into the opening or pass the edge trim
SimpliFire Scion and Triton Fold out brackets, connect power, set and fasten the unit, then finish the wall Scion: trim for finishes under 1 in.; no trim for stone or brick over 1 in.
SimpliFire Allusion Platinum and Edge Frame, wire, finish and paint the wall, then slide the unit in Finish 1/4 to 1 in. thick (Platinum) or 1/4 to 1-1/2 in. (Edge); the trim overlaps it
SimpliFire Allusion Slim Cut or frame the opening, connect power, set and fasten the unit into the finished wall The front trim overlaps the opening and must not be covered by finish materials

Steps and who does them

  1. Pick the model and get its manual (you, with us): framing sizes change by width, so frame from the manual for your exact size.
  2. Decide voltage and connection (you and your electrician): 120V or 240V, plug kit or hardwire. This has to happen before framing. See below.
  3. Frame the opening or chase (carpenter or builder): the Ignite XL and Astound manuals both state the unit is not load-bearing, so the framing carries the wall and finish above it. Cutting a wide opening in an existing wall may mean cutting studs, so have a builder size the header.
  4. Electrical rough-in (licensed electrician): run the circuit and leave the cable where the manual puts the connection, for example bottom right on the Ignite XL and top right on the Astound Built-In. Your area may require a permit and inspection before the wall closes.
  5. Set the unit and finish the wall (carpenter, drywall or tile installer): in the order your model's manual gives. Keep insulation and vapor barrier away from units that require it: Revillusion wants at least 2 in. above the firebox, and Napoleon says no insulation against the Astound.
  6. Glass, media and trim (installer or you): several manuals call for two people to lift the unit or fit the glass.

Building a 2x6 media wall for an Ignite Evolve? Our Ignite Evolve framing and wiring guide covers that build step by step, and our mantel clearance guide lists the gap each model needs above it.

Type 3: Into an existing masonry fireplace

An electric firebox can bring an unused wood-burning fireplace back to life without venting or a gas line. Two models we carry are described by their makers for this: Dimplex sells the Revillusion 24 as a way to "update and finish an existing fireplace," and the Napoleon Element 42 retrofits an existing opening at least 41-1/2 in. wide, 31-1/4 in. high and 13-3/4 in. deep.

  1. Measure the firebox (you): old fireboxes taper, so measure at the front and again 9 and 12 inches in, top and bottom. The unit must clear the smallest number.
  2. Clean, inspect and seal the chimney (chimney professional): Dimplex advises sealing drafts and capping the flue, and not installing in a fireplace prone to dampness.
  3. Get power to the firebox (licensed electrician for any new outlet): Dimplex's insert guidance allows an outlet inside the fireplace or the cord run along the hearth to an outlet nearby. No extension cords.
  4. Set, level and trim (you or an installer): shim level, then close the gap to the masonry with a trim kit or surround.

The full measuring and chimney checklist is in our electric insert for a wood-burning fireplace guide.

Power options, in brief

The connection method is the single biggest factor in whether you need an electrician. Here is what each manufacturer lists:

Model Plug-in option Hardwire
TriVista Pictura 60 Yes, 120V 120V option in the manual
Astound FlexMount 50 Yes, 120V 120V or 240V
Allusion Slim, Platinum, Edge Yes, 120V cord (included with the Slim; optional on the Edge) 120V
Ignite XL and Evolve Yes, 120V plug kit 120V or 240V (240V is hardwire only)
Astound Built-In No Required, 120V or 240V
Scion and Triton Not described 120V or 240V
Revillusion 24 Yes, 120V grounding plug 120V option
Revillusion 30 to 42 Accessory, 120V only Standard; 120V, 208V or 240V
Ignite Aspire Plug kit included 120V or 240V
Element 42 Yes, 120V 240V must be hardwired
Inception 36 Cord only with the Wescott mantel kit 120V or 240V

On models with a 240V option, 240V adds heat, not flame. It needs a new circuit from the panel and is far easier to run while the wall is open. The SimpliFire, Napoleon and Dimplex manuals all recommend or require a dedicated circuit, and SimpliFire specifies that all electrical connections be made by a qualified electrician. Our electrical requirements guide explains circuits, amps and where the outlet can and cannot go.

DIY, electrician or contractor?

You can often handle it yourself when the fireplace is a plug-in wall-mount or slide-in unit, there is a suitable grounded outlet the cord reaches without an extension, and you can fasten into studs or solid masonry.

Hire a pro when:

  • Any hardwiring, new outlet or new circuit is involved. That is a licensed electrician's job under local code, and every 240V installation falls here.
  • You are opening an existing wall. A builder should check for studs, wiring, plumbing or ductwork in the cavity and size a header for a wide opening.
  • The wall is exterior. SimpliFire notes that exterior walls in cold climates may need an insulated chase under local code.
  • The finish is stone, tile or a trimless look. Tolerances are tight and the order of work matters.
  • It is going into a bathroom. SimpliFire's Allusion Slim manual, for example, calls for GFI protection in a bathroom, and local electrical code sets its own rules there.
  • You are converting a wood-burning fireplace. Have a chimney professional inspect and seal it first.

Our installation and pro services page explains how we can refer local installers where available, or send a technical package to your own contractor.

What goes into the cost

Labor rates vary too much by region and job to quote a reliable national figure, so get local quotes for the items that apply to you:

  • The fireplace and accessories: trim kits, plug kits, surrounds or mantel kits where needed.
  • Electrical: a new outlet, a hardwired connection, or a new dedicated circuit from the panel (more involved for 240V or a long run).
  • Framing: cutting and heading an opening, or building a chase or media wall.
  • Finishing: drywall, paint, tile, stone or millwork.
  • Chimney work for an existing fireplace: cleaning, inspection, sealing and capping.
  • Permits and inspection where your building department requires them.

Ask each contractor to price from the manual for your exact model, so everyone quotes the same opening size and wiring.

How long does it take?

A plug-in wall mount is typically a single session once you have the outlet you need. A built-in takes longer because it moves through trades in sequence: framing, electrical rough-in, any inspection, finishing, then setting the unit or fitting glass and media. Ask your contractor to schedule around your model's order of work and any inspection your area requires.

Installation planning checklist

  1. Choose the installation type: wall-mounted, recessed or into an existing fireplace.
  2. Confirm the wall: 2x4 or 2x6 studs, interior or exterior, and the clear width.
  3. Pick the model and download its installation manual for your exact size.
  4. Decide voltage (120V or 240V) and connection (plug or hardwire) before any framing.
  5. Mark the outlet or junction box position per the manual, keeping receptacles out of the heat path above the unit.
  6. Plan what goes above: mantel, TV or shelving, against the manual's clearances.
  7. Confirm the order of work: does your model go in before or after the wall is finished?
  8. For an existing fireplace: measure at three depths, and book a chimney inspection.
  9. Check with your building department about permits.
  10. Line up the trades: electrician, carpenter, finisher, and a second person for lifting and glass.

Common questions

Can I install an electric fireplace myself?

Often, for a plug-in wall-mount or a slide-in firebox near a suitable outlet. Framing an opening is carpentry work many homeowners hire out, and any hardwiring or new circuit should go to a licensed electrician.

Do electric fireplaces need venting?

No. The models in this guide need no chimney or vent. Dimplex states the Revillusion requires no special venting. If you install in an old fireplace, the chimney should be sealed so it stops pulling warm air out.

Can I plug a built-in electric fireplace into an outlet?

Some, at 120V only. The Ignite XL, Evolve, Allusion series and Aspire offer a cord or plug kit. The Astound Built-In must be hardwired, and every 240V installation is hardwired.

Do I need a permit?

It depends on where you live and what the job includes. New circuits and structural changes commonly need one. Ask your building department or electrician before work starts.

Next step

Tell us your wall type, width and whether you can open the wall, and we will match a model and send the manual pages your contractor needs. Use our electric fireplace fit check for a new wall, the electric insert fit check for an existing fireplace, or contact us. You can also browse all electric fireplaces or linear electric fireplaces.

Sources

This guide is for planning and product selection. It does not replace the installation manual for your exact model, your local building and electrical codes, or a licensed electrician and qualified installer. Manufacturers revise their documents, so always install from the manual supplied with your fireplace.