Short answer: measure four things inside your firebox: front width, back width, height and depth, each at its narrowest point. Then compare them with each insert's minimum opening. The smallest Kingsman insert we carry, the Capri 24 (IDV24), needs at least 24-1/4 in. wide at the front, 19-1/4 in. across the back, 18-1/2 in. high and 14 in. deep. The largest, the IDV44, needs 32-7/8 in. at the front, 25-3/4 in. across the back, 25-3/4 in. high and 18 in. deep. The IDV26 and IDV34 fall in between. Your chimney also has to be at least 12 ft tall for the vent liner.
This guide covers all four Kingsman direct vent inserts we carry (the Capri 24, 34 and 44 and the Capella 26), using Kingsman's current installation manuals and brochures. It is for planning only. A certified gas installer has to confirm the fit before you order. If you are already set on the IDV26, our IDV26 measuring guide goes deeper on that model's front options.
Why the number in the model name isn't your opening size
People often search for a "36 inch gas fireplace insert" because their fireplace opening is about 36 in. wide. But the number in an insert's name does not match the opening it needs. The IDV34 needs a front width of 28-5/8 in., and the IDV44 needs 32-7/8 in. A 36 in. wide opening may take any of the four inserts. Whether it does depends on the other three measurements, and the back width and depth rule out a model more often than the front width does.
The insert slides into the firebox. A front, and an optional surround, then covers the gap between the insert and the edges of your opening. So you need two kinds of measurements: the inside of the firebox, which decides which insert fits, and the outer opening face, which decides which front or surround will cover it.
How to measure your fireplace for an insert
Use a tape measure and write down every number to the nearest 1/8 in. Remove the grate, screen and any glass doors first so you can reach the firebox walls.
- Front width. Measure side to side across the front of the opening, just inside the brick or metal face. Do it at the bottom, middle and top, and keep the smallest number.
- Back width. Measure side to side along the back wall. Masonry fireboxes usually taper toward the back, so this number is often much smaller than the front width. It is the measurement people skip most often.
- Height. Measure from the firebox floor to the lowest point at the top of the opening. That is usually the underside of the steel lintel or the bottom edge of the damper frame, not the top of the brick face.
- Depth. Measure from the front edge of the opening to the back wall at floor level. Measure again partway up, because many back walls slope forward, and keep the smaller number.
- Outer opening face. Measure the width and height of the opening as you see it from the room, edge to edge on the brick, stone or metal face. You need this to choose a front or surround that covers it.
- Chimney height. Estimate the height from the firebox floor to the top of the chimney. Your chimney sweep or installer can measure this accurately.
- Hearth and mantel. Measure the hearth in front of the fireplace (depth, width and thickness), and the height of any mantel above the opening and how far it projects from the wall.
- Photos. Take a straight-on photo of the fireplace and one looking into the firebox. Note anything that sticks out, such as a damper handle, smoke shelf or uneven brick.
Kingsman's manuals allow the flue damper to be removed or fixed fully open for the insert. Your installer will decide whether anything in the throat of the fireplace has to come out. You don't need to remove it to take your measurements, but measure height to the lowest fixed obstruction.
Minimum fireplace opening for each Kingsman insert
These are Kingsman's published minimum openings. Every one of your four inside measurements must be equal to or larger than the figure for that model.
| Insert | Front width | Back width | Height | Depth |
|---|---|---|---|---|
| Capri 24 (IDV24) | 24-1/4 in. | 19-1/4 in. | 18-1/2 in. | 14 in. |
| Capella 26 (IDV26), wide front (controls out) | 28 in. | 22 in. | 19-1/2 in. | 14-1/4 in. |
| Capella 26 (IDV26), slim front (controls in) | 33 in. centered, 31 in. off-center | 22 in. | 19-1/2 in. | 14-1/4 in. |
| Capri 34 (IDV34), I34CV1 front | 28-5/8 in. | 21-1/4 in. | 21-1/2 in. | 17-3/4 in. |
| Capri 34 (IDV34), I34CV6 front | 26-7/8 in.* | 21-1/4 in. | 21-1/2 in. | 15-3/4 in. |
| Capri 44 (IDV44) | 32-7/8 in. | 25-3/4 in. | 25-3/4 in. | 18 in. |
From the Kingsman installation manuals for the IDV24 (24IDV-MAN19), IDV26 (26IDV-MAN19) and IDV34/44 (34IDV-MAN19). *Kingsman's December 2025 brochure lists 26-1/4 in. for the IDV34 with the I34CV6 front, while the manual lists 26-7/8 in. We use the larger manual figure. Our IDV34 product page currently offers the I34CV1 front, so ask us if your firebox only fits the I34CV6 dimensions.
A few things stand out:
- The IDV24 is the smallest. It needs the least on all four measurements, so it is the one to check first for a small or shallow fireplace.
- The IDV26 needs less width than the IDV34, but more across the back. With a wide front and the controls moved outside the opening, the IDV26 needs only 28 in. at the front. It does need 22 in. across the back, which is more than the IDV34's 21-1/4 in.
- Depth splits the range in two. The IDV24 and IDV26 need about 14 in. of depth. The IDV34 needs 15-3/4 or 17-3/4 in. depending on the front, and the IDV44 needs 18 in.
- The IDV44 needs a large, square-ish firebox. Its back width and height are both 25-3/4 in.
Which size fits: a quick way to choose
Start with the largest insert and work down. The first model where all four of your measurements meet or beat the minimums is the largest that fits. A smaller model will also fit, so you can still choose it if you prefer its look or heat output.
| If your firebox measures at least... | Largest insert that fits |
|---|---|
| 32-7/8 in. front, 25-3/4 in. back, 25-3/4 in. high, 18 in. deep | IDV44 (all four fit) |
| 28-5/8 in. front, 21-1/4 in. back, 21-1/2 in. high, 17-3/4 in. deep | IDV34 with I34CV1 front |
| 26-7/8 in. front, 21-1/4 in. back, 21-1/2 in. high, 15-3/4 in. deep | IDV34 with I34CV6 front (confirm availability with us) |
| 28 in. front, 22 in. back, 19-1/2 in. high, 14-1/4 in. deep | IDV26 (wide front under 31 in.; any front at 31 in. off-center or 33 in. centered) |
| 24-1/4 in. front, 19-1/4 in. back, 18-1/2 in. high, 14 in. deep | IDV24 |
| Less than the IDV24 on any measurement | None of these inserts. See the alternatives below. |
Three worked examples
These are example measurements, not real customer fireplaces, to show how one number can change the answer.
- Front 36 in., back 27 in., height 29 in., depth 20 in. Every measurement clears the IDV44's minimums, so all four inserts fit. The choice comes down to looks and heat.
- Front 30 in., back 24 in., height 24 in., depth 16 in. The IDV44 is too wide and too deep. The IDV34 with the I34CV1 front needs 17-3/4 in. of depth, so it is out, but the I34CV6 dimensions fit. The IDV26 fits with a wide front, because 30 in. is under the 31 in. needed for a slim front. The IDV24 fits too.
- Front 28 in., back 20 in., height 22 in., depth 15 in. The front width looks fine for the IDV26, but the 20 in. back wall is under its 22 in. minimum and under the IDV34's 21-1/4 in. Only the IDV24 fits. This is why the back width matters.
Insert and front dimensions
Once you know which inserts fit inside, the front decides how the finished fireplace looks and whether it covers your opening face. Compare your outer opening measurement with these Kingsman sizes (width x height). Each insert needs a front. A surround adds a larger border for openings the front alone won't cover.
| Insert | Viewing area | Standard front | Larger surround options |
|---|---|---|---|
| IDV24 | 20-13/16 x 11 in. | Clean View I24CV1: 30-1/2 x 21-7/16 in. | Surround 37-13/16 x 27 in.; picture frame 37-13/16 x 28-7/8 in.; universal 45 x 41 in. (cut to size) |
| IDV26 | Not listed in the brochure | Clean View I26CV1 or I26CV3: 35-5/8 x 22-3/4 in. | Clean View I26CV2: 44-5/8 x 26-5/8 in.; picture frames 35-5/8 x 25-7/8 in. and 44-7/8 x 33-1/2 in. |
| IDV34 | 25-5/8 x 14-1/8 in. | Clean View I34CV1: 35-1/4 x 24-3/16 in. | Surround 39 x 27-5/16 in.; picture frame 41-1/8 x 31-3/8 in.; universal 45 x 41 in. (trim to size) |
| IDV44 | 29-7/8 x 18-3/8 in. | Clean View I44CV1: 39-9/16 x 28-1/2 in. | Surround 44 x 32-1/16 in.; picture frame 44 x 36 in.; universal 47 x 42 in. (trim to size) |
Sizes are from Kingsman's IDV24/34/44 brochure (B103, December 2025) and IDV26 brochure (B076, 2025). Our product pages offer a selection of these fronts and surrounds for each model. If your opening face is larger than the options shown, send us its measurements and we'll check which front covers it.
Check your chimney before you choose
Every one of these inserts is direct vent. It runs two flexible liners up the existing chimney, one bringing in outside air and one carrying exhaust out, joined at a co-linear cap on top. The chimney is a chase for those liners. Kingsman's requirements:
- Height. The manuals list a vertical vent run of at least 12 ft and no more than 40 ft, with no more than 2 ft of horizontal offset. A short chimney on a one-story home is worth measuring first. For the IDV44, the table appears in the IDV34 section of the shared manual, so have your installer confirm it.
- Liner sizes. The IDV26 and IDV34 use two 3 in. liners. The IDV44 uses a 4 in. exhaust liner and a 3 in. intake liner. The IDV24 uses two 3 in. liners, or, for a 6 in. chimney, Kingsman's 2 in./3 in. adapter kit, which limits the vertical run to 25 ft.
- Condition. A chimney that served a wood fireplace must be professionally cleaned, and inspected and repaired as needed, before the liners go in. The insert cannot share a flue with another solid-fuel appliance.
- Cold climates. Kingsman recommends insulating the chimney cavity with non-combustible insulation, especially for chimneys on an exterior wall.
Our direct vent venting guide explains how sealed venting works.
Masonry or factory-built fireplace?
Kingsman's manuals say these inserts are designed for two kinds of wood-burning fireplace:
- Masonry fireplaces built to code from non-combustible materials. Kingsman says not to remove refractory materials from a masonry fireplace.
- Listed zero-clearance factory-built fireplaces, the metal wood-burning fireboxes framed into many homes. Kingsman notes the damper plate, refractory liners, grates, glass doors and screen parts may need to come out, and the smoke baffle usually does. Cutting any sheet-metal part of the existing fireplace is prohibited. If there is no gas access hole, the manuals allow one hole of 1-1/2 in. or less through the lower side or bottom, sealed with non-combustible insulation afterward.
If you have a factory-built fireplace, find its rating plate and keep its manual if you have it. Your installer should check that label and your local code alongside the Kingsman manual before confirming an insert. Measure a factory-built firebox the same way, but note that the metal walls and refractory panels may sit at angles.
Not sure which you have? Our zero-clearance vs. insert guide explains the difference, and our wood-to-gas conversion guide covers the wider project.
Hearth, floor and mantel
All four manuals require a non-combustible floor under the insert. The IDV26 manual also requires a hearth in front at least 3/4 in. thick, 12-1/2 in. deep and 31 in. wide. For the other models, your installer will check the hearth against the clearance diagrams in the manual.
A wooden or other combustible mantel has to sit high enough above the insert, and the deeper it projects, the higher it has to be. Kingsman's minimum combustible mantel heights, from the shallowest to the deepest mantel shown in each manual:
| Insert | Mantel height range in the manual | With I33CS mantel shield |
|---|---|---|
| IDV24 | 31-1/8 in. (flush) to 41-1/8 in. (10 in. deep) | Same heights |
| IDV26 | 35-3/8 to 45-3/8 in. | 28-1/2 to 38-1/2 in. |
| IDV34 | 36 in. (flush) to 44-1/2 in. (8 in. deep) | 30 to 38 in. |
| IDV44 | 40 in. (flush) to 46 in. (8 in. deep) | 34 to 42 in. |
Heights are measured as shown in each manual's mantel diagram. The IDV26 manual measures from the bottom of the unit. A non-combustible mantel can go lower, but combustible objects should not sit on it unless it meets the combustible heights. If your mantel is low, a smaller insert may be the deciding factor. Have your installer read the exact figure for your mantel depth from the manual.
Bigger isn't always warmer
Once you know what fits, compare heat. These are Kingsman's maximum input ratings in BTU/h:
| Insert | Natural gas max / min | Propane max / min |
|---|---|---|
| IDV24 | 24,000 / 16,750 | 24,000 / 20,000 |
| IDV26 | 28,500 / 19,500 | 28,000 / 23,000 |
| IDV34 | 31,000 / 20,900 | 28,500 / 23,100 |
| IDV44 | 34,250 / 24,000 | 30,000 / 22,840 |
Kingsman's current IDV26 installation manual (26IDV-MAN19, October 2025) lists 28,500 BTU (natural gas) and 28,000 BTU (propane); its 2025 brochure lists 30,000 for both. The rating plate on your unit is final. Either way, the IDV26 is rated within a few thousand BTU of the IDV34, so a mid-size firebox doesn't have to mean much less heat. For matching output to your room, see our gas fireplace sizing guide. If your home runs on a tank, our propane fireplace guide covers what changes.
Power and other planning items
- Power. The blower plugs into a grounded three-prong outlet. Kingsman says the millivolt and IPI valve systems still work during a power failure, but the blower won't run.
- Gas. The insert needs a gas line run to the fireplace by a licensed gas fitter, sized and pressure-tested for your fuel.
- Venting parts. The IDV26, IDV34 and IDV44 manuals approve Kingsman flex liner kits or specific MG DuraVent kits; the IDV24 manual approves Kingsman venting only. Venting is ordered separately from the insert.
Measuring checklist
- Front width (smallest of three readings)
- Back width
- Height to the lowest point of the lintel or damper frame
- Depth at the floor and higher up (smaller of the two)
- Outer opening face, width and height
- Chimney height from firebox floor, and whether it is on an exterior wall
- Masonry or factory-built, plus a photo of any rating plate
- Hearth depth, width and thickness
- Mantel height above the opening and how far it projects
- Natural gas or propane
- Photos: straight-on and into the firebox
If none of these inserts fits
If your firebox is shallower than 14 in., lower than 18-1/2 in., narrower than 24-1/4 in. at the front or under 19-1/4 in. across the back, none of these inserts will fit. If your chimney is under 12 ft or unusable, the vent liner won't work either. Two options to discuss with us:
- An electric insert, which needs no chimney or gas line. Our electric insert guide covers fit and power. Or browse our electric fireplace inserts.
- A new zero-clearance gas fireplace framed into the wall, if you are open to a larger remodel. See our direct vent gas fireplaces.
Common questions
What is the smallest gas fireplace insert Lumiflares carries?
The Kingsman Capri 24 (IDV24). It needs a minimum opening of 24-1/4 in. wide at the front, 19-1/4 in. across the back, 18-1/2 in. high and 14 in. deep.
Can I install the insert myself?
We don't recommend it. A gas insert involves gas piping, venting and clearances that must follow the manual and local code, so plan on a qualified, licensed gas installer, and check whether your town requires a permit. Our IDV26 review and other guides cover what to expect.
Next step
Send your measurements through our free gas insert fit check and we'll tell you which inserts and fronts fit your fireplace. You can also browse all gas fireplace inserts, or the full range of gas fireplaces, or contact us with your photos and questions.
Sources
- Kingsman IDV24 installation manual, 24IDV-MAN19
- Kingsman IDV26 installation manual, 26IDV-MAN19 (Oct 1, 2025)
- Kingsman IDV34/IDV44 installation manual, 34IDV-MAN19
- Kingsman IDV24/34/44 brochure, B103 (12/2025); also B103 (01/2024)
- Kingsman IDV26 brochure, B076 (2025); also B076 (08/2023)
This guide is for planning and product selection. It does not replace your insert's installation manual, the original fireplace's listing, local codes, or a certified gas installer, who must confirm the fit before you order. Manufacturers may change specifications, so always install from the manual supplied with your unit.